Claim tracker · Cardio & VO2 max
What heart rate is zone 2, and do the formulas work?
Experts define zone 2 as just below your first lactate or ventilatory threshold. In lab tests, that threshold fell anywhere between 60% and 90% of maximum heart rate, so one formula can't place everyone correctly.
Who paid for the 5 studies cited1 independent4 funding not reportedHow we label funding
Claim trackerOverstatedBThe claim
“Your zone 2 is a simple percentage of your max heart rate — just plug in your age.”
Our verdict
There is a real kernel, but the claim inflates the size, certainty or relevance of the effect.
Why grade B: A laboratory study of 100 adults with measured lactate thresholds shows fixed percentages of maximum heart rate fit individual thresholds poorly, and age-based maximum heart-rate equations predict group averages, not individuals. The evidence is consistent and direct, but comes from relatively small lab samples, so B rather than A. How we grade
In three bullets
Key takeaways
- A 2025 expert panel defined zone 2 as intensity just below the first lactate or ventilatory threshold, not as a fixed heart-rate percentage.
- In 100 adults tested in a lab, the lactate threshold occurred anywhere from 60% to 90% of maximum heart rate, so any single percentage put many people in the wrong intensity domain.
- Age formulas estimate average maximum heart rate: a 2001 analysis found 208 − 0.7 × age and concluded that 220 − age underestimates it in older adults, and wrist heart-rate sensors were reasonably accurate at steady effort but less so when activity changed.
What the research actually says
Last evidence update:
This article is based on the published abstracts of the studies.
“Zone 2” is one of the most searched training terms. Most apps turn it into a heart-rate range from your age. Does that work?
How labs define zone 2
In 2025, a panel of 14 sport scientists and coaches agreed that zone 2 should sit just below your first lactate or ventilatory threshold: the point where lactate in the blood and breathing first start to rise. That is a physiological marker, not a fixed percentage.
Age-based formulas vs lab tests
Two separate steps go into a formula-based zone, and both add error.
- Estimating your maximum heart rate. A large 2001 analysis of 18,712 people found maximum heart rate fell with age along the line 208 − 0.7 × age, and that the familiar 220 − age underestimates it in older adults. Both are averages: your own maximum can be well above or below.
- Taking a percentage of it. In a 2020 lab study, 100 adults had their lactate threshold measured directly. It occurred anywhere from 60% to 90% of maximum heart rate. Any single percentage put many people in the wrong intensity zone, and thresholds sat at a higher percentage in women than men.
The talk test
A simple alternative is to exercise at the fastest pace at which you can still speak comfortably. In a small study of 15 young adults, that point lined up with the measured lactate threshold. It is cheap and personal, but has been tested mainly in small groups.
How accurate wrist heart-rate zones are
Wrist sensors use light to detect blood flow. In a 2020 study, they were reasonably accurate at rest and during steady exercise, with no significant difference across skin tones, but error was on average 30% higher during activity than at rest, and devices differed. Steady zone 2 sessions are the easier case.
Does the exact zone matter for longevity?
Not as much as the debate suggests. The expert panel noted that zone 2 benefits may also come from slightly higher or lower intensities, and a 2025 review argued that higher intensities matter for heart and metabolic health. We cover the bigger question in Is zone 2 the best cardio for longevity?.
Verdict
Overstated, grade B. Zone 2 is real and easy to approximate, but a heart-rate formula based on age can’t reliably find it for an individual: the underlying threshold ranged from 60% to 90% of maximum heart rate in lab tests.
Key studies (5)
What Is "Zone 2 Training"?: Experts' Viewpoint on Definition, Training Methods, and Expected Adaptations
Sitko S, Artetxe X, Bonnevie-Svendsen M, Galán-Rioja MÁ, Gallo G, Grappe F, et al.. International Journal of Sports Physiology and Performance, 2025. DOI: 10.1123/ijspp.2024-0303. PMID: 40010355.
- Design
- Expert commentary (panel of 14 applied sport scientists and professional coaches)
- Who
- Not applicable (expert opinion)
- Main result
- Consensus that zone 2 training should preferably be performed at intensities immediately below the first lactate or ventilatory threshold. Expected adaptations might not be unique to zone 2 and could also come from slightly higher or lower intensities.
- Limitations
- Expert opinion, not new data; the panel notes there is no prior consensus definition.
Who paid for this studyFunding not reported
Funding not reported in the sources we could access.
Source: PubMed · checked 13 November 2026
A Critical Evaluation of Current Methods for Exercise Prescription in Women and Men
Iannetta D, Inglis EC, Mattu AT, Fontana FY, Pogliaghi S, Keir DA, et al.. Medicine & Science in Sports & Exercise, 2020. DOI: 10.1249/MSS.0000000000002147. PMID: 31479001.
- Design
- Laboratory study: ramp-incremental test (VO2max, peak work rate, maximal heart rate, lactate threshold) plus 30-minute constant-load trials to find maximal lactate steady state
- Who
- Adults (46 women, 54 men)
- Main result
- The lactate threshold occurred between 60% and 90% of maximal heart rate (and 45%–74% of VO2max); maximal lactate steady state between 75% and 97% of maximal heart rate. Thresholds occurred at a higher percentage of VO2max and maximal heart rate in women than men. Fixed percentages of maximum values conformed poorly to individual intensity domains.
- Limitations
- Lab study in 100 people; sample characteristics (age, fitness) in the paper.
Who paid for this studyFunding not reported
Funding not reported in the sources we could access.
Declared interests: PubMed flags non-US-government support without naming it.
Source: PubMed · checked 13 November 2026
Age-predicted maximal heart rate revisited
Tanaka H, Monahan KD, Seals DR. Journal of the American College of Cardiology, 2001. DOI: 10.1016/s0735-1097(00)01054-8. PMID: 11153730.
- Design
- Meta-analysis of group mean maximal heart rates, cross-validated in a laboratory study
- Who
- Healthy adults
- Main result
- Maximal heart rate was strongly related to age (r = −0.90), fitting 208 − 0.7 × age; the lab study gave 209 − 0.7 × age. The authors conclude the common 220 − age equation underestimates maximal heart rate in older adults.
- Limitations
- Predicts average maximal heart rate for a group; individuals vary around the line.
Who paid for this studyPublic / non-profit funding
Paid for by US National Institute on Aging.
Source: PubMed · checked 13 November 2026
The Talk Test and its relationship with the ventilatory and lactate thresholds
Quinn TJ, Coons BA. Journal of Sports Sciences, 2011. DOI: 10.1080/02640414.2011.585165. PMID: 21774751.
- Design
- Laboratory study comparing the Talk Test with measured lactate and ventilatory thresholds
- Who
- Adults aged 18–35 (13 men, 2 women)
- Main result
- Heart rate and VO2 at all Talk Test stages were higher than at the ventilatory threshold; values at the 'comfortable' and 'not sure' stages were similar to the lactate threshold. At the last comfortable-speaking stage, participants were at 64% of VO2max and 82% of maximal heart rate on average.
- Limitations
- Very small, young, mostly male sample.
Who paid for this studyFunding not reported
Funding not reported in the sources we could access.
Source: PubMed · checked 13 November 2026
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent B, Goldstein BA, Kibbe WA, Dunn JP. npj Digital Medicine, 2020. DOI: 10.1038/s41746-020-0226-6. PMID: 32047863.
- Design
- Laboratory comparison of consumer- and research-grade wearables across skin tones and activity types
- Who
- Adults across the full range of skin tones
- Main result
- No statistically significant difference in accuracy across skin tones, but significant differences between devices and activity types; absolute error during activity was on average 30% higher than at rest. Devices were reasonably accurate at rest and during prolonged elevated heart rate.
- Limitations
- Specific device models tested in 2019–2020; newer devices may differ.
Who paid for this studyFunding not reported
Funding not reported in the sources we could access.
Declared interests: One author was supported by a Duke fellowship; the authors declare no competing interests.
Source: full text (PMC) · checked 13 November 2026
| Outcome | Direction | Certainty |
|---|---|---|
| A fixed % of max heart rate matches each person's first threshold | ○ No clear effect | EvidenceGoodgrade B |
| Age formulas predict an individual's true max heart rate | ? Unclear | EvidenceLimitedgrade C |
| Talk test tracks the lactate threshold | ↑ Benefit | EvidenceWeakgrade D |
| Wrist heart rate is accurate during steady exercise | ↑ Benefit | EvidenceLimitedgrade C |
Where the claim comes from
'Zone 2' became popular through endurance coaching and longevity podcasts. Many apps and articles translate it into a heart-rate range from a formula based on age, such as a percentage of 220 minus your age, or a single number subtracted from a constant.
What experts and guidelines say
- Editorial note
If you have heart disease, high blood pressure or take medicines that affect heart rate (such as beta-blockers), heart-rate formulas may not apply to you; talk to your doctor before planning exercise intensity.
Practical takeaway
Zone 2 is defined by your physiology: just below the point where lactate and breathing start to rise. Heart-rate formulas give a rough starting point for groups but can be well off for an individual, because that threshold varied from 60% to 90% of maximum heart rate in lab tests. A lab test measures it directly; the talk test (exercising at a pace where you can still speak comfortably) is a simple, free approximation, though it has been studied mainly in small groups.
This is general information, not individual medical advice. Talk to a clinician before changing medication, or if you are pregnant, have a chronic condition or take prescription drugs.
What would change our verdict
- Large studies showing a specific age-based formula places most people within their measured zone 2.
- Validation of consumer devices' zone estimates against lab-measured thresholds.
Verdict history
| Date | Verdict | Grade | Why |
|---|---|---|---|
| 10 November 2026 | VerdictOverstated | Evidence grade B (Good) | Initial draft verdict, before editorial review. |
Every dated check of this claim
No dated checks of this claim yet. When we publish one, it will be listed here.
Changelog
- UpdateUpdated: added study funding (who paid for each cited study, from the papers' funding and competing-interest statements, PubMed, Crossref or the trial registry).
- PublishedPublished after pre-publication checks (DOIs/PMIDs re-verified, no retraction notices, numbers matched to the PubMed abstracts).
- UpdateFirst draft prepared (AI-assisted), before editorial review. Not public at this stage.
Spotted an error? Report it — we log every correction publicly on our corrections page.
References
- Sitko S, Artetxe X, Bonnevie-Svendsen M, Galán-Rioja MÁ, Gallo G, Grappe F, et al.. What Is "Zone 2 Training"?: Experts' Viewpoint on Definition, Training Methods, and Expected Adaptations. International Journal of Sports Physiology and Performance. 2025.DOI 10.1123/ijspp.2024-0303PubMed 40010355
- Iannetta D, Inglis EC, Mattu AT, Fontana FY, Pogliaghi S, Keir DA, et al.. A Critical Evaluation of Current Methods for Exercise Prescription in Women and Men. Medicine & Science in Sports & Exercise. 2020.DOI 10.1249/MSS.0000000000002147PubMed 31479001
- Tanaka H, Monahan KD, Seals DR. Age-predicted maximal heart rate revisited. Journal of the American College of Cardiology. 2001.DOI 10.1016/s0735-1097(00)01054-8PubMed 11153730
- Quinn TJ, Coons BA. The Talk Test and its relationship with the ventilatory and lactate thresholds. Journal of Sports Sciences. 2011.DOI 10.1080/02640414.2011.585165PubMed 21774751
- Bent B, Goldstein BA, Kibbe WA, Dunn JP. Investigating sources of inaccuracy in wearable optical heart rate sensors. npj Digital Medicine. 2020.DOI 10.1038/s41746-020-0226-6PubMed 32047863
- Storoschuk KL, Moran-MacDonald A, Gibala MJ, Gurd BJ. Much Ado About Zone 2: A Narrative Review Assessing the Efficacy of Zone 2 Training for Improving Mitochondrial Capacity and Cardiorespiratory Fitness in the General Population. Sports Med. 2025 (concludes zone 2 is not the optimal intensity for mitochondrial capacity; one author reports equity in an exercise-related company).DOI 10.1007/s40279-025-02261-yPubMed 40560504
Newsletter
The Verdict
A short newsletter of graded longevity research is planned. Signup is not open yet.
Coming soon. We are not collecting emails yet. Read new research on the site or via RSS.