Research · Biomarkers & Ageing Clocks · Cardio & VO2 max
Do smartwatch heart alerts predict future stroke or heart failure?
A new analysis of the Apple Heart Study links irregular-rhythm notifications to higher odds of later cardiovascular events.
Who paid for the 2 studies cited2 industry-funded2 with industry tiesHow we label funding
ResearchMostly supportedCThe question we graded
Does getting an irregular-rhythm alert from a smartwatch signal a higher risk of heart failure, stroke and other heart events?
Our verdict
The core of the claim holds, but a detail (dose, population, size of effect) is off or uncertain.
Why grade C: A very large cohort (293,944 people) with strong, consistent associations. Graded C because it is a post hoc analysis of a single-arm study, the heart events were self-reported, follow-up was 5 to 14 months, the alert group differed in risk factors, and we could read only the abstract. How we grade
In three bullets
Key takeaways
- Receipt of a smartwatch irregular-rhythm notification was associated with significantly higher adjusted odds of subsequent heart failure, stroke, and pulmonary embolism.
- The association persisted even among participants who did not have confirmed atrial fibrillation, suggesting the alert may identify broader cardiovascular risk.
- Findings are observational and based on self-reported events over a short follow-up period, meaning causation cannot be established.
What the research actually says
What the study did
A new analysis published online on November 23, 2026, in Circulation: Arrhythmia and Electrophysiology investigates whether receiving an irregular-rhythm notification (IRN) from a smartwatch is linked to future cardiovascular problems. The paper, titled “Cardiovascular Outcomes Following Smartwatch Irregular Rhythm Notification: Findings From the Apple Heart Study,” represents a post hoc analysis of data from the larger Apple Heart Study.
The researchers evaluated whether receipt of an IRN was associated with subsequent self-reported cardiovascular events among participants who completed the end-of-study survey. The exposure variable was simply whether a participant received an irregular-rhythm notification during their time in the study. The outcomes measured were self-reported new diagnoses of heart failure, myocardial infarction (heart attack), stroke or transient ischemic attack (TIA), pulmonary embolism, and a composite measure known as major adverse cardiovascular events (MACE).
The analysis included 293,944 participants who completed follow-up surveys. These surveys were administered between 5 to 14 months after enrollment. To isolate the association between the notification and heart events, the researchers used multivariable-adjusted logistic regression models. These models controlled for several potential confounders, including age, sex, history of heart failure, hypertension, diabetes, prior stroke/TIA/systemic embolism, and vascular disease.
It is important to note that this analysis is based on the published abstract; we could not access the full text of the paper. Consequently, detailed methodological nuances beyond what is summarized in the abstract are not available for review. The study design was a post hoc analysis of a prospective single-arm trial, meaning it was not a randomised controlled trial.
What it found
Among the 293,944 participants who completed follow-up, only 929 individuals (0.32% [95% CI, 0.30%-0.34%]) received an irregular-rhythm notification during the study period. The analysis revealed that participants who did receive an IRN were generally older, more often male, and carried a greater burden of cardiovascular risk factors compared to those who did not.
Despite adjusting for these baseline differences, the receipt of an IRN was associated with significantly higher adjusted odds of subsequent self-reported cardiovascular events. Specifically:
- Heart failure: The adjusted odds ratio was 5.43 (95% CI, 3.09-9.57).
- Stroke/transient ischemic attack: The adjusted odds ratio was 3.51 (1.91-6.45).
- Pulmonary embolism: The adjusted odds ratio was 4.43 (1.92-10.20).
- Major adverse cardiovascular events (composite): The adjusted odds ratio was 4.01 (2.80-5.73).
Notably, the association remained significant even among a subset of participants who received an IRN but did not have confirmed atrial fibrillation. In this group, IRN receipt was still associated with statistically significantly higher adjusted odds of self-reported heart failure and major adverse cardiovascular events. The authors concluded that these findings suggest IRNs may identify individuals at elevated short-term cardiovascular risk beyond just those with atrial fibrillation.
What it doesn’t show
While the association between smartwatch alerts and later heart events is striking, several limitations prevent us from drawing definitive causal conclusions. First, the outcomes were self-reported by participants via survey rather than verified through medical records or clinical diagnosis. Self-reported events can be inaccurate, and the abstract gives no information about verification.
Second, this was a post hoc analysis of a single-arm study, not a randomised trial. Randomisation helps balance known and unknown confounders between groups; without it, residual confounding is always a concern. Although the statistical models adjusted for age, sex, hypertension, diabetes, prior stroke/TIA/systemic embolism, vascular disease, and history of heart failure, there may be other unmeasured factors that differ between those who receive alerts and those who do not.
Third, the follow-up period was relatively short, ranging from only 5 to 14 months after enrollment. This limits our understanding of whether these associations persist over longer periods. Additionally, the abstract does not specify whether the reported events were medically verified or based solely on participant recall.
Finally, the study reports odds ratios, which are not the same as relative risks. Only 929 of the 293,944 participants (0.32%) received an alert, and the abstract does not give absolute event counts, so we cannot say how many events lay behind these odds ratios.
How it fits with earlier research
This new paper asks a different question than the original report from the same study cohort. The 2019 main report published in the New England Journal of Medicine tested whether the smartwatch alert could identify atrial fibrillation. This new analysis extends the inquiry to broader cardiovascular outcomes, examining what an alert might signal regarding future heart failure, stroke, and other major cardiac events. In that 2019 report, 2,161 of 419,297 participants (0.52%) received a notification, and among 450 who returned usable ECG patches, 34% had atrial fibrillation. We have also covered a study testing whether a consumer smartwatch can flag high blood pressure (our report).
Who paid for the research
The parent study, registered as ClinicalTrials.gov NCT03335800 (“Apple Heart Study: Assessment of Wristwatch-Based Photoplethysmography to Identify Cardiac Arrhythmias”), lists Apple Inc. as the lead sponsor. Apple is an industry entity that manufactures the smartwatch and its irregular-rhythm notification feature. While the registry confirms Apple’s role, the funding sources and competing interest disclosures for this specific follow-up analysis were not accessible in the paper itself or via PubMed at the time of verification. For the original 2019 report, the NEJM paper states that Apple sponsored the study and owns the data, and some of its authors were Apple employees. Because the company that makes the device sponsored the parent study, readers should keep that in mind, although the main findings here concern heart events reported by participants rather than the device’s accuracy.
Verdict
Mostly supported (Grade C)
The evidence mostly supports the idea that receiving an irregular-rhythm notification from a smartwatch is associated with a higher risk of subsequent cardiovascular events, including heart failure and stroke. The association was strong and persisted even after adjusting for major risk factors and in participants without confirmed atrial fibrillation.
However, the grade is C because the data comes from a single observational post hoc analysis with self-reported outcomes and a short follow-up period. Observational studies can show associations but cannot prove causation. It remains possible that individuals who receive alerts have underlying health conditions or risk factors not fully captured by the adjustment variables, which drive both the alert generation and the subsequent heart events.
If you receive an irregular-rhythm notification from your wearable device, it is reasonable to discuss it with your doctor to determine if further evaluation is warranted, but these findings should not be interpreted as a guarantee of future health outcomes.
Key studies (2)
Cardiovascular Outcomes Following Smartwatch Irregular Rhythm Notification: Findings From the Apple Heart Study.
Perez-Guerrero E, Parsa S, Gjermeni D, Sakalaki M, Yu K, Hedlin H, Desai M, Alipour P, Russo AM, Granger CB, Kowey PR, Hills MT, Rumsfeld J, Turakhia MP, Mahaffey KW, Perez MV; Apple Heart Study Investigators. Circulation: Arrhythmia and Electrophysiology, 2026. DOI: 10.1161/CIRCEP.126.015256. PMID: 43070171.
- Design
- Post hoc analysis of the Apple Heart Study, a prospective, app-based single-arm study in the United States
- Who
- Participants in the Apple Heart Study who completed follow-up surveys
- Main result
- Among 293,944 participants, 929 (0.32% [95% CI, 0.30%-0.34%]) received an irregular rhythm notification (IRN). IRN receipt was associated with higher adjusted odds of self-reported heart failure (odds ratio, 5.43 [95% CI, 3.09-9.57]), stroke/transient ischemic attack (odds ratio, 3.51 [1.91-6.45]), pulmonary embolism (odds ratio, 4.43 [1.92-10.20]), and major adverse cardiovascular events (odds ratio, 4.01 [2.80-5.73]). Among participants with an IRN but without atrial fibrillation, IRN receipt remained associated with statistically significantly higher adjusted odds of self-reported heart failure and major adverse cardiovascular events.
- Limitations
- Heart events were self-reported in a survey; the abstract does not say whether they were medically confirmed.
- Post hoc analysis of a single-arm study, not a randomised trial; people who got alerts were older, more often male and had more cardiovascular risk factors, despite adjustment.
- Short follow-up (5 to 14 months); based on the published abstract only.
Who paid for this studyIndustry-funded
Paid for by Apple Inc.. Apple, which makes the smartwatch and its irregular-rhythm notification feature, is the registered lead sponsor of the Apple Heart Study; funding and competing interests for this follow-up analysis could not be checked in the paper itself. Industry ties: a funder makes or sells the product tested.
Source: trial registry · checked 25 November 2026
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Perez MV, Mahaffey KW, Hedlin H, et al.. New England Journal of Medicine, 2019. DOI: 10.1056/NEJMoa1901183. PMID: 31722151.
- Design
- Pragmatic, siteless, app-based study of irregular-pulse notifications from a consumer smartwatch, with ECG patch follow-up in notified participants
- Who
- US adults using a compatible Apple Watch and iPhone who enrolled via an app (the parent study of the new analysis)
- Main result
- 2,161 participants (0.52%) received irregular-pulse notifications. Among 450 who returned analysable ECG patches, atrial fibrillation was present in 34%; the positive predictive value of a notification for concurrent atrial fibrillation on the ECG was 0.84.
- Limitations
- Self-selected app users; many notified people did not complete ECG patch follow-up.
Who paid for this studyIndustry-funded
Paid for by Apple. Apple sponsored the study and owns the data; the analyses were done by Stanford statisticians independent of the sponsor. Industry ties: a funder makes or sells the product tested; company employees are co-authors.
Declared interests: Some authors are Apple employees (NEJM author list).
Source: full text (PMC) · checked 13 November 2026
| Outcome | Direction | Certainty |
|---|---|---|
| Heart failure | ↓ Harm | EvidenceLimitedgrade C |
| Stroke/TIA | ↓ Harm | EvidenceLimitedgrade C |
| Pulmonary embolism | ↓ Harm | EvidenceLimitedgrade C |
| Major adverse cardiovascular events (composite) | ↓ Harm | EvidenceLimitedgrade C |
Practical takeaway
Smartwatch irregular-rhythm notifications are associated with higher odds of subsequent self-reported cardiovascular events, including heart failure and stroke, even in the absence of confirmed atrial fibrillation. However, these findings come from an observational post hoc analysis with short-term follow-up and cannot show why alerts and later heart events go together, or whether acting on an alert changes what happens. If you get an alert, discuss it with your doctor.
This is general information, not individual medical advice. Talk to a clinician before changing medication, or if you are pregnant, have a chronic condition or take prescription drugs.
Changelog
- PublishedPublished after pre-publication checks (DOI/PMID re-verified, no retraction notices, all numbers matched to the PubMed abstracts, sponsor confirmed in the trial registry; based on the abstract).
- UpdateFirst draft prepared (AI-assisted), before editorial review. Not public at this stage.
Spotted an error? Report it — we log every correction publicly on our corrections page.
References
- Perez-Guerrero E, Parsa S, Gjermeni D, Sakalaki M, Yu K, Hedlin H, Desai M, Alipour P, Russo AM, Granger CB, Kowey PR, Hills MT, Rumsfeld J, Turakhia MP, Mahaffey KW, Perez MV; Apple Heart Study Investigators. Cardiovascular Outcomes Following Smartwatch Irregular Rhythm Notification: Findings From the Apple Heart Study.. Circulation: Arrhythmia and Electrophysiology. 2026.DOI 10.1161/CIRCEP.126.015256PubMed 43070171
- Perez MV, Mahaffey KW, Hedlin H, et al.. Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation. New England Journal of Medicine. 2019.DOI 10.1056/NEJMoa1901183PubMed 31722151
Newsletter
The Verdict
A short newsletter of graded longevity research is planned. Signup is not open yet.
Coming soon. We are not collecting emails yet. Read new research on the site or via RSS.