Independent, science-first No supplement money Every article checked against the sources

Latest update

Verdict · Biomarkers & Ageing Clocks · Cardio & VO2 max

Is the VO2 max number on your smartwatch accurate?

Watches that estimate VO2 max from workouts are close on average across groups of people, but for any one person the estimate can be off by a lot. Resting-based estimates do worse.

Our rating

How we rate
VerdictMixed / context missingEvidenceGoodgrade B

Who paid for the study cited1 industry-fundedHow we label funding

01

The claim

The claim

“Your smartwatch tells you your VO2 max, so you don't need a lab test anymore.”

Common claim (illustrative wording)
02

Our verdict

VerdictMixed / context missing

Evidence points both ways, or the claim is technically true but misleading without key context.

EvidenceGoodgrade B

Why grade B: One systematic review and meta-analysis of 14 validation studies against lab testing, with consistent findings on individual-level error; devices and algorithms change quickly, so newer models may differ = B. How we grade

03

In three bullets

Key takeaways

  • A 2022 meta-analysis of 14 validation studies compared watch and wearable VO2 max estimates with lab treadmill or bike tests.
  • Devices that estimate from exercise data were close on average (bias about −0.1 mL/kg/min), but individual readings could be off by roughly ±10 mL/kg/min. Devices using only resting data overestimated by about 2 mL/kg/min, with even wider error.
  • The authors said the estimates are useful at the population level but not yet accurate enough for individual sport or clinical decisions. Tracking your own trend over time is a different question that the review didn't settle.
04

What the research actually says

VO2 max is the most oxygen your body can use during hard exercise. Measuring it properly means running or cycling to exhaustion while wearing a mask that analyses your breath. Smartwatches estimate it instead, usually from your heart rate at a given pace, plus your age, sex and weight.

What the validation studies show. A 2022 systematic review and meta-analysis pooled 14 studies that compared consumer wearables against lab tests. It split devices by how they estimate. Those using data from exercise were almost spot on on average: a bias of −0.09 mL/kg/min. But the limits of agreement, which show how far an individual reading can fall from the true value, ran from about −10 to +10 mL/kg/min. Devices using only resting data overestimated by about 2 mL/kg/min on average, with limits of roughly −13 to +17.

To put that in context, the meta-analysis of training trials in our VO2 max coverage found that months of training raise VO2 max by about 5 mL/kg/min on average, so the possible error in a single watch reading is larger than a typical training gain.

What that means. The authors concluded that exercise-based estimates seem good enough for studying groups of people, but that the error for an individual is large and needs to improve before the numbers are used for sport or clinical decisions. They also set out standards for future validation studies, because existing ones varied a lot in how they were done.

What the review couldn’t tell us. Devices and algorithms change quickly, so the review can’t say how today’s models perform. It also didn’t test whether a watch correctly tracks changes in your own fitness over time, which is how many people actually use the number.

Verdict. Watch estimates are reasonable on average but can be far off for you personally. “No need for a lab test” holds for casual tracking, not for an accurate measurement. Mixed.

Key studies (1)

Meta-analysisHumansn = 14 validation studies

Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-analysis and Expert Statement of the INTERLIVE Network

Molina-Garcia P, Notbohm HL, Schumann M, et al.. Sports Medicine, 2022. DOI: 10.1007/s40279-021-01639-y. PMID: 35072942.

Design
Systematic review and meta-analysis of validation studies, with an expert statement (INTERLIVE network)
Who
Adults in validation studies comparing consumer wearables with laboratory VO2 max tests
Main result
Wearables using resting-condition algorithms overestimated VO2 max (bias 2.17 mL/kg/min; 95% limits of agreement −13.07 to 17.41). Those using exercise-based algorithms had lower error (bias −0.09; limits of agreement −9.92 to 9.74). The authors concluded the estimation error at the individual level is large.
Limitations
  • Covers devices and firmware validated up to about 2021; algorithms are updated often.
  • Validation protocols varied; the authors propose standards for future studies.

Who paid for this studyIndustry-funded

Paid for by Huawei Technologies Oy (Finland) Co. Ltd.. Huawei Technologies Oy (Finland) Co. Ltd. partly funded the research.

Source: full text (PMC) · checked 18 November 2026

Correction published · checked 29 October 2026Notices found: Crossref 10.1007/s40279-026-02547-9 (correction); PubMed Sports Med. 2026 Oct 13. doi: 10.1007/s40279-026-02547-9. [ErratumIn].DOI resolves ✓ · PMID matches ✓
Evidence table: outcome, direction of effect and certainty
OutcomeDirectionCertainty
Exercise-based wearable estimates match lab VO2 max on average↑ BenefitEvidenceGoodgrade B
Wearable estimates are accurate for an individual○ No clear effectEvidenceGoodgrade B
Resting-based estimates overestimate VO2 max↓ HarmEvidenceLimitedgrade C
05

Where the claim comes from

Many smartwatches now show a 'VO2 max' or 'cardio fitness' score, usually estimated from heart rate during walks or runs, plus age, sex and weight. Because VO2 max is linked to lifespan in large studies, these numbers get a lot of attention.

06

Practical takeaway

A watch estimate can give you a rough idea of your fitness and may help you see a trend if you measure in the same way over time. But a single reading may be well off your true value, so don't read too much into small changes, and don't use it to judge your heart health. If you need an accurate number, for example for a medical reason, a lab test is the reference.

This is general information, not individual medical advice. Talk to a clinician before changing medication, or if you are pregnant, have a chronic condition or take prescription drugs.

07

What would change our verdict

  • Independent validation of current devices and algorithms against lab tests, in diverse groups including older and less fit people.
  • Studies of how well watch estimates track changes in the same person over time.

Our explainer: Does VO2 max predict how long you live?

08

Changelog

  1. UpdateUpdated: added study funding (who paid for each cited study, from the papers' funding and competing-interest statements, PubMed, Crossref or the trial registry).
  2. PublishedPublished after editorial review.
  3. UpdateFirst draft prepared (AI-assisted), before editorial review. Not public at this stage.

Spotted an error? Report it — we log every correction publicly on our corrections page.

09

References

  1. Molina-Garcia P, Notbohm HL, Schumann M, et al.. Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-analysis and Expert Statement of the INTERLIVE Network. Sports Medicine. 2022.DOI 10.1007/s40279-021-01639-yPubMed 35072942

Newsletter

The Verdict

A short newsletter of graded longevity research is planned. Signup is not open yet.

Coming soon. We are not collecting emails yet. Read new research on the site or via RSS.

Browse research